Product introduction

New Aqua (for drinking water)

New Aqua (for drinking water)

Application
– For drinking water (underground reservoirs, water purification plants, swimming pools, fisheries)
– Hot water tanks
– Stainless tanks (PE, PP, SMC)
– Drinking water structures exposed to corrosion environment
Product configuration
New Aqua solvent (for drinking water) is state-of-the-art new material that can solve problems derived from lifting and failure in adhesion and hardening while carrying out construction in water and wet areas. It is a special paint and coating agent for drinking water, which can be applied to anti-corrosion, water-proof and dust-proof steel structure, and concrete structure.
Product characteristics

– It provides strong adhesion regardless of the material type such as wet concrete, steel plate, and stainless material.
-It is odorless and can be applied for underground reservoir construction..
– Crack does not occur at a temperature of 50℃ below zero.
– Crack does not occur at 100℃ of hot water. (construction in hot water tanks)
– It can be finished with 2 time processing without using primer.
– High-pressure cleaning should be applied for pre-processing.
– This product has been qualified in anti-ozone testing.
– It is the test product with zero neutrality.
– It has been qualified in oil testing. (gasoline, diesel, lamp oil)
– (gasoline, diesel, lamp oil)

Product characteristics
Type of surface Recommended thickness for the membrane Construction area
concrete 700㎛ 24㎡
Steel material 300㎛ 60㎡
Epoxy 500㎛ 35㎡
How to use and caution
How to use – It removes hindrance factor for adhesion in the construction part using high-pressure cleaning (pressure of 150 bar or more).
– After high-pressure cleaning, pin hole and caved part can be cleaned using putty or G-103.
– After high-pressure cleaning and drying, New Aqua can be mixed with electronic stirrer and applied for 1st construction.
– Mix with electronic mixer for 3 minutes so that failure does not occur.
– For 1st construction, membrane thickness should be 300 μm or more.
– 2nd construction should be carried out 12 hours (25℃) after the 1st construction.
– For 2nd construction, membrane thickness should be 400 μm or more.
– After checking complete hardening, high-pressure cleaning is recommended using fresh water.
caution – It should not be exposed to direct sunlight and should be stored in cool indoor area.
– For construction where surface temperature is under 5℃, consult with the company.
– Do not use the diluent made by another company.
– It is recommended to use boiling water for the construction in winter season.
– For using diluent, consult with the company. (odorless diluent)